Tripp Lite SMART1200XLHG - SmartPro120V1kVA750WMedical-Grade-werUPS
Slide 1 of 1

Manufacturer
Tripp Lite
MPN
SMART1200XLHG
Available
0
Condition
New
SmartPro120V1kVA750WMedical-Grade-werUPS
The Tripp Lite SMART1200XLHG is a high-quality medical-grade uninterruptible power supply (UPS) designed to provide reliable backup power for critical equipment in healthcare facilities. With a capacity of 1kVA/750W, this UPS is capable of supporting a wide range of medical devices, including computers, monitors, and diagnostic equipment.
It is also equipped with a built-in isolation transformer, which provides enhanced protection against electrical noise and interference, ensuring the safe and reliable operation of sensitive medical equipment. It also features a hospital-grade plug and outlets, providing a secure and reliable connection to power sources. It also offers advanced features such as automatic voltage regulation (AVR) and surge protection, which help to safeguard equipment from damaging power fluctuations.
Features:
- Ideal UPS Backup in Healthcare Facilities
- Complies with UL 60601-1 standards for use in patient-care facilities
- Isolation transformer with Faraday shield offers full isolation and removes common mode noise
- 6 ft. power cord with 120V NEMA 5-15P-HG plug
- Floating AC output prevents noise coupling and meets agency requirements for isolation
Reliable Battery Backup and Surge Protection
- Supports half load up to 28 min. and full load up to 10 min.
- 4 NEMA 5-15R-HG outlets with 940-joule surge protection
- Filters out disruptive EMI/RFI line noise that can cause equipment damage or data loss
- Resists electrostatic discharge
LEDs and Audible Alarms
- Front LEDs indicate power, mode, load and battery status
- Alarms alert you to power failure, overload and low battery
- Mute/quiet mode ideal for use in quiet patient-care vicinities
Saves Files When You’re Away
- Included PowerAlert® software enables safe, unattended system shutdown and file saving during power failures
- Connects to computer via DB9 or USB port with included cables
Specifications | |
INPUT | |
| Input Phase | Single-Phase |
| Rated input current (Maximum Load) | 9.2A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS Input Connection Type | 5-15P-HG |
| Input Circuit Breakers | 15A |
| UPS Input Cord Length (ft.) | 6 |
| Recommended Electrical Service | 15A 120V |
| Maximum Input Amps | 9 |
| Input Cord Length (ft.) | 6 |
OUTPUT | |
| Output Capacity (VA) | 1000 |
| Output Capacity (kVA) | 1 |
| Output Capacity (Watts) | 750 |
| Output Capacity (kW) | 0.75 |
| Power Factor | 0.8 |
| Frequency Compatibility | 60 Hz |
| Output Voltage Regulation (Line Mode) | -18%, +8% |
| Output Voltage Regulation (Battery Mode) | 115V (+/- 5%) |
| Output Receptacle Details | Hospital grade output receptacles |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Nominal Output Voltage(s) Supported | 115V; 120V |
| Output Receptacles | (4) 5-15R |
BATTERY | |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Runtime Full Load (min.) | 10 min. (750W) |
| Runtime Half Load (min.) | 28 min. (375W) |
| Expandable Runtime | Yes |
| DC System Voltage (VDC) | 36 |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
| Battery Access | Battery access door |
| Internal UPS Replacement Battery Cartridge | RBC36SLT |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143 |
| Overvoltage Correction | Input voltages between 126 and 143 are reduced by 9% |
| Undervoltage Correction | Input voltages between 96 and 106 are boosted by 10% |
| Severe Undervoltage Correction | Input voltages between 81 and 95 are boosted by 21% |
USER INTERFACE, ALERTS & CONTROLS | |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Audible Alarm | Factory-muted audible alarm indicates power-failure, overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
ISOLATION | |
| Output Isolation Transformer | Hospital grade load isolation transformer |
| Leakage Current | Less than 100 microamps |
SURGE / NOISE SUPPRESSION | |
| EMI / RFI AC Noise Suppression | Yes |
| AC Suppression Joule Rating | 940 |
| AC Suppression Response Time | Instantaneous |
PHYSICAL | |
| Primary Form Factor | Tower |
| Rack Height | 0U |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Installation Form Factors Supported with Optional Accessories | Wallmount ( UPSWM - tower mounting kit) |
| Primary UPS Depth (mm) | 241 |
| Primary UPS Height (mm) | 318 |
| Primary UPS Width (mm) | 191 |
| UPS Housing Material | PVC |
| UPS Power Module Dimensions (hwd, in.) | 12.5 x 7.5 x 9.5 |
| UPS Power Module Weight (kg) | 20.50 |
| UPS Power Module Weight (lbs.) | 45.2 |
| Unit Weight (lbs.) | 45.260 |
ENVIRONMENTAL | |
| Operating Temperature Range | 32° to 104°F (0° to 40°C) |
| Storage Temperature Range | 5° to 122°F (-15° to 50°C) |
| Relative Humidity | 0-95% non-condensing |
| AC Mode BTU / Hr. (Full Load) | 162.8 |
| AC Mode Efficiency Rating (100% Load) | 94% |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 315.2 |
| Battery Mode Heat Dissipation (BTU/Hr) @ Half Load | 190.5 |
COMMUNICATIONS | |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| Communications Cable | USB and DB9 serial cabling included |
| Network Management Card Description | Network management not supported |
| Communications Interface | USB; DB9 Serial |
LINE / BATTERY TRANSFER | |
| Transfer Time | 2-4 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) | 81 |
| High Voltage Transfer to Battery Power (Setpoint) | 143 |
FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Hot swappable batteries; Surge/noise protection |
| Grounding Details | Grounding lug (equipotential) |
APPLICATIONS | |
| UPS Applications | Hospital/Medical |